Pdf selective, highspeed clearance of faults on high voltage transmission lines is critical to the security of the power system. Protection at the secondary side of the transformer transformer secondary protection although ocpds are required as primary protection for transformers with no exception, there are a few scenarios where overcurrent protection is not required at the transformer secondary, as per tables 450. Unlike phase and neutral overcurrent protection, the key advantage of distance protection is that its fault coverage of the protected circuit is virtually independent of source impedance variations. System conditions, particularly during emergency operations, may make it necessary for transmission lines and transformers to become overloaded for short periods o f time.
Introduction transmission lines are a vital part of the electrical distribution system, as they provide the path to transfer power between generation and load. Nec guidelines for transformer and transformer feeder. Directional non directional overcurrent protection. England and wales transmission system within ngets national grid electricity transmission. Directional overcurrent protection elements are a fundamental part of the protection schemes of transmission lines around the world, since in all meshed transmission networks, it is impossible to ensure selectivity without limiting the operation of the overcurrent protection devices for just one direction, as indicated in 1,2. Im looking at a protection scheme in a 69kv switchyard and i notice that all of the outgoing 69kv transmission lines use distance protection but some of the outgoing lower voltage 12. Overcurrent protection protects electrical power systems against excessive currents which are caused by short circuits, ground faults, etc. Over current protection of transmission line using gsm and arduino.
Phase distance protection can be divided into five distinct. Arresterfacts 017 what is a transmission line arrester copyright arresterworks 2009 jonathan j. This led to other spctf papers illustrating ways to use legacy and. Consider a case of a radial line supplying three substation as shown in fig. Characteristic settings of directional overcurrent relays. These factors play vital role on protect against of transmission towers and lines of the electrical system. Identify, apply, and calculate settings for transmission line protection schemes, including directional overcurrent, distance, and pilot protection schemes. Discuss the advantages of line current differential protection. Overcurrent relays for transmission line protection. Basic complements of such relays are two phase and one ground relays. Please rate the video and provide your comment on dr s krishnamurthy, senior lecturer, deece, cput, south africa email. However, distance relaying for groundfault primary and backup protection of transmission lines is slowly replacing overcurrent relaying.
When coordinating distance and overcurrent elements, it is common for high probability double contingency cases n. Their role has been to provide protection for ground faults by applications that have included an instantaneous element in combination with an inverse time overcurrent element. The behavior of ground overcurrent protection on double circuit applications is also discussed in the paper. Transmission line setting calculations college of continuing and. Each relay protection device comprises a definitetime delay overcurrent protection relay in which the trip of the current sensitive element starts the time delay device. Suppose we set relay current setting such that it can protect 5. Earth fault protection an overview sciencedirect topics. We know that in transmission line lg,llg,lll fault takes place. What are the reasons that overcurrent relays are not used. Hence apparent impedance is susceptible to an error of 20%. Pdf the implementation of distance protection relay in.
These tests need two engineers at each end of the line to simulate normal and fault conditions and to check the relay response at both ends of the line and also to check the decision for tripping the circuit breakers cbs at the two. Nonpilot overcurrent protection of transmission lines 4. Transmission line applications of directional ground. Why are overcurrent relays not used for primary protection of ehv lines in spite of the fact that instantaneous over current relays exist. The main use of tdoc relays is on a radial system where they are used for both phase and ground. Overload or overcurrent protection owes its application to the fact that the fault current in the event of a short circuit will raise to a value several times that of the maximum load current. The overcurrent relays, line current monitors, and the interposing transducers exhibit finite accuracy. Overcurrent protection relay electrical substation. Protection of lines or feeder august 31, 2018 february 24, 2012 by electrical4u as the length of electrical power transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of electrical power transformers and alternators.
Tutorial on distance and over current protection erpc. Transmission line setting calculations beyond the cookbook. Fault impedance of different fault is follow like this lgllglll so lg fault has maximum impedance over other faults. Three zone protection by using distance relays in simulink. Abstract this project is about designing the controls of an over current relay using a microcontroller. Transmission relay loadability, codified requirements for loadability of phase responsive transmission relays which in some cases significantly limited the ability of some relays to provide backup protection. Available fault current is affected by changes in the power system source impedance, and thus, the ground overcurrent element is susceptible to varying system conditions. Many types of protective relays are used to protect power system equipments, they are classified according to their operating principles. Pdf distance protection for electrical transmission line. If we consider about the protection of transmission line there are three protection types are used to protect these lines. In this project, the protection of the transmission lines in typical ieee, 9busbars grid has been investigated in detail.
Because the transmission system configuration may change over a period of. It is also observed the waveforms of voltages and currents by simulating the transmission line with and without faults also. Digsilent implementation of overcurrent protection scheme. Link between source to transmission line ratio and protection relay voltage a electrical power system arrangement b change of protection relay voltage with electrical system source to transmission line impedance ratio the above universal relationship between v r and zszl, presented in figure 5, is true. A transmission line is defined by the location of the circuit breakers or other sectionalizing devices that isolate the line from other parts of the system and include sections of bus, overhead. Over current relaying and fuse protection uses the principle that when the current exceeds a predetermined value, it indicates presence of. Each protection unit comprises a definitetime delay. Key words switch gear protection, distance relay, line protection, matlabsimulink, impedance. Transmission line protection principles ge grid solutions. Using distance protection vs overcurrent protection. Nonpilot overcurrent protection of transmission lines. Line protection with overcurrent relays 259 lines are protected by overcurrent, distance, or pilotrelaying equipment, depending on the requirements. The transmission line and load was modeled using distributed parameters line and threephase load block sets respectively. Directional non directional directional non directional overcurrent protection p120 phase ii v11 p121 phase ii v12 p122 phase ii v12.
For simplicity in explaining the key ideas, we consider three phase bolted faults. Finally, some advanced features of communications assisted schemes, noncommunications protection schemes and fault location for double circuit lines are discussed. Transmission lines operate at voltage levels from 69kv to 765kv, and are ideally tightly interconnected for reliable operation. Transmission line applications of direction ground overcurrent. Directionality plays an important role in transmission line protection.
Fundamental overcurrent, distance and differential. One should study the diagram to develop an understanding. Transmission system protection the discussion of transmission line protection begins with the definition of a transmission line. Describe timedomain ultrahighspeed transmission line. We use four protection principles for distribution and transmission lines. The typical applications are overhead lines, underground cables and backup for hv systems in insulated, solid, resistance and petersen coil earthed. Line protection with overcurrent relays ge grid solutions. However, the relay logic would disable these phase overcurrent elements during normal conditions. Overcurrent relay protection is given at b, c, d and e, that is, at the infeed position of each part of the electrical power system. Transmission systems are generally looped systems, that is, there are many sources and current can flow in any direction. Overcurrent relaying is the simplest and cheapest, the most difficult to apply, and the quickest to need readjustment or even replacement as a system changes.
Overcurrent protection of transmission and distribution lines overcurrent protection is the simplest and most economical of tl protection schemes. While faults with fault impedance are not as common on the transmission system as in distribution systems, the severity and adverse consequences of a transmission line fault that is. Overload or overcurrent protection owes its application to the fact that the fault current in the event of a short circuit will raise to a. Overcurrent relays can be used to protect practically any power system elements, i. Because the amount of current flow is somewhat unpredictable, overcurrent relay settings would. Distance protection, in its basic form, is a nonunit system of protection offering considerable economic and technical advantages. Transmission line applications of direction ground. Electrical power transmission line protection systems. Sel introduced the worlds first digital relay in 1984, revolutionizing the power protection industry by offering fault locating and other features for a fraction of the cost of earlier systems. Transmission line protection using directional ground overcurrent elements has several limitations. Supplied with tecquipments protection and relay test set psl50, the relay enables investigations into protection and monitoring of transformers, transmission lines and distribution schemes. This scheme is based on the intuition that, faults typically short circuits, lead to currents much above the load current. To be done on transmission lines differential protection and distance relay telecommunications tripping schemes. The function of transmission protection systems included in the referenced reliability standard is to protect the transmission system when subjected to faults.
Using directional relays eases coordination by reducing the number of relays that must coordinate together for a single fault. Describe the various pilot protection schemes for transmission lines. This can protect the line for all combinations of phase and ground faults using the minimum number of relays. This is the simplest way of protecting a line and is, therefore, widely used. In the years since, we have grown and developed a complete line of products and services for the protection, monitoring, control, automation, and metering of electric power systems. Overcurrent protection is provided at b, c, d and e, that is, at the infeed end of each section of the power system. Directional ground overcurrent relays have been an essential component in protection of transmission lines for as long as any of us have been around.